Carrier 48fc 15 ton - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

 
 SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. . Products offered by tractor supply co. union city

CE - carrierenterprise.comPerformance Features. New unit control board with intuitive quick fan speed adjustment. New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-28 models. SEERs to 14.3, IEER of 15.0. HSPF to 8.2 and COP’s to 3.6.25SCA5. Up to 15.2 SEER2 for moderate energy savings with standard comfort features. 4.5 out of 5 stars. 32 Reviews. 5 Star. 69%. 4 Star. 22%. 3 Star. With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn more and see how we've put a ... View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air … Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. We would like to show you a description here but the site won’t allow us.Carrier 48TC Gas/Electric 15 Ton Standard Efficiency Packaged Outdoor Unit 208/230-3-60 MED Static, Medium Heat ... Same footprint as installed Carrier 3-12.5 ton rooftops back to 1989, reducing installation costs and time ... PI-48FC-GC-01; Checklist - PI48TC-HC-01; Configuration - 33CS-68SI;CE - carrierenterprise.comView and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ...With solutions from 10 through 500 tons, screw or scroll, Carrier air-cooled chillers are the best choice for your needs. With a wide range of air-cooled chiller scroll and screw types, capacities (10 to 500 tons) and sustainable refrigerant options, Carrier is a leader in the industry. Whether it be non-ozone depleting refrigerant, simple ...6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.CE - carrierenterprise.comCarrier delivers efficient, dependable performance, inside and out. With Carrier split systems, a wide range of outdoor air conditioners and heat pumps works seamlessly with innovative indoor air handlers to create reliable solutions that are easy-to-install and service for a wide range of commercial HVAC needs. 10 Product (s)S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andCarrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (101 pages) ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ...Catalog No. 04-53480288-01 Printed in U.S.A. View and Download Carrier WeatherMaker 48TC Series service and maintenance instructions online. Single Package Rooftop Unit with Gas Heat/Electric Cooling and Puron (R-410A) Refrigerant. WeatherMaker 48TC Series air conditioner pdf manual download.Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup-SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ... 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ...All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners. 24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).According to the U.S. Energy Information Administration, as of March 2014, the cost of coal per short ton ranged from $12 to $65. The quality of the coal determines the pricing of ...7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …Carrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News. Home; 2024-03-04; 2024-03-03; 2024-03-02; ... Carrier 48FC Single Package Rooftop Gas Heat-Electric Cooling Units Instruction Manual.48TCED14A2A6-0A0A048 = Gas Heat Packaged RooftopTC = WeatherMaker™ Standard EfficiencyE = Medium HeatD = Two Stage Cooling Models 08-1614 = 12.5 tonsA = None2 = Belt Drive, Medium Static OptionA = Al/Cu - Al/Cu6 = …Catalog No. 04-53480288-01 Printed in U.S.A. View and Download Carrier WeatherMaker 48TC Series service and maintenance instructions online. Single Package Rooftop Unit with Gas Heat/Electric Cooling and Puron (R-410A) Refrigerant. WeatherMaker 48TC Series air conditioner pdf manual download.48ES, 48VL, 48XL Small Packaged Products Air Conditioner / Gas Furnace Family REVIT Files. 48XZ, 48VT, 48XT Small Packaged Products Air Conditioner / Hybrid Heat Family REVIT Files. 50ES, 50VL, 50XL Small Packaged Products Air Conditioner Family REVIT Files. 50EZ, 50VT, 50XT Small Packaged Products Heat Pump Family REVIT Files.Carrier Manuals. Air Conditioner. 48TC series. Product data. Carrier WeatherMaker 48TC Series Product Data. Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons. Also See for WeatherMaker 48TC Series: Service and maintenance instructions (112 pages) , Installation instructions manual (64 pages) ,24SPA636W003 24 = AC w/ R-410A / Product Series / Refrigerant S = Single Stage / Design Type P = Performance Series / Tier A = Initial / Major Series 6 = 16 SEER2 36 = 3 Ton / Cooling Capacity W = Standard SW AC / Region 0 = Standard / Feature 0 = Standard / Special Feature 3 = 208/230-1 / Voltage NOTE: Ratings are subject to change at any …20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.There are already plenty of monopolies in big tech. Google isn't alone....GOOGL Alphabet Inc. (GOOGL) and its Google are playing scapegoat this Sunday. The tech giant is expect...Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.4 ARI* CAPACITIES Cooling Capacities and Efficiencies UNIT 48ES NOMINAL TONS STANDARD CFM NET COOLING CAPACITIES (Btuh) EER** SEER† 024 2 800 23,000 11.0 13.2 030 2--1/2 1000 28,600 11.2 13.5 036 3 1200 34,400 11.0 13.0 042 3--1/2 1400 40,500 11.2 13.2 048 4 1600 46,500 11.2 13.2 060 5 1750 57,000 11.0 13.4 LEGENDDrawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...There are 2,000 pounds in one ton. Tons and pounds are both units of measurement that describe mass. The abbreviation for ton is “T,” while the abbreviation for pound is “lb” or “l...48VG. Gas heating and electric cooling with up to 16 SEER2 for enhanced energy savings with enhanced comfort features. Ultra-low NOx models available for California. 4.7 out of 5 stars. 45 Reviews. 5 Star. 80%. 4 Star. 13%. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor) 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... 48FCFM07A1A5-0A0A0 - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Standard STATIC 208/230 ... 48fcfm07a3a5-0a0a0_submittal; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input …CE - Carrier EnterpriseProduct Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor)48 50FC 8 16 01PD Carrier Nominal 10 Ton 11 2 EER Package RTU Cooling Only Two Stage 208 3 siglers mw link id 10646 ||| Product Data WeatherMaker Single Packaged Rooftop 7.5 to 15 Nominal Tons 2023 Carrier 48/50FC**08, 09, 12, 14, 16 48FC: Single-Package Gas Heating/Electric Cooling Rooftop Units 50FC: Electric Cooling Rooftop …When it comes to finding the perfect fifth wheel for your needs, there are a few key factors to consider. Fifth wheels are a great option for those who want to enjoy the comforts o...Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C) Innovative …Carrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.3. IEERs up to 15.0 and heating HSPFs up to 8.2. All models are capable of either vertical or horizontal airflow.10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for … 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ... 24SPA636W003 24 = AC w/ R-410A / Product Series / Refrigerant S = Single Stage / Design Type P = Performance Series / Tier A = Initial / Major Series 6 = 16 SEER2 36 = 3 Ton / Cooling Capacity W = Standard SW AC / Region 0 = Standard / Feature 0 = Standard / Special Feature 3 = 208/230-1 / Voltage NOTE: Ratings are subject to change at any … New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Two-stage cooling capacity control (sizes 08 to 24) Up to 13.4 SEER, 12.2 IEER, 11.2 EER, HSPF 7.7, and COP 3.4. Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit. Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.38AU Gemini™ Commercial Split-System Air-Cooled Condensing Units & 40RU Air Handling Units. 38AUD 10-12 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 15 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 20 Ton Packaged Air Cooled Condenser Units, Dual …NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)Carrier 48fc 10 Ton, Carrier Commercial Packaged Outdoor Units Melrose Park, IL, WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology ... 2023-12-24; 2023-12-23; 2016-02-15; 2012-12-24; 2016-01-28; 2015-09-27; 2022-10-19; carrier 48fc 10 ton. RTU Curb Adapters Welded Curb Adapters Curbco. Carrier 48FC …Carrier Enterprise Mid-Atlantic Technical Support SiteView and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with R-410A …14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert onlyAll WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.View and Download Carrier 48TC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 04-07 with Puron (R-410A) Refrigerant. 48TC air conditioner pdf manual download. Also for: 48tc-a04, 48tc-a05, 48tc-a06, 48tc-a07. IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit We detail the scrap brass prices per pound, ounce, and ton. Find prices for common iron brass, plus rarer types like leaded red brass ingot. Jump Links Brass is worth around $1.25 ...Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48TCA04---A12 Service And Maintenance Instructions. ... Page 15 Table 2 – Unit Wire/MOCP Sizing Data NO C.O. or UNPWRD C.O. COMBUSTION ...CarrierCarrier 48FC Installation Instructions (2 pages) Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory. Manual is suitable for 4 more products: 48 GC 48 HC 48 LC 48 TC. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB.3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial; Gas Stages 1-Stage;CE - Carrier EnterpriseFor example, using a R--22 gas heat, electric cooling, 6--ton unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust. MCA New = 28.9 amps + 1.7 amps = 30.6 amps If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps, the MCA New is below 35, therefore the …Carrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.3. IEERs up to 15.0 and heating HSPFs up to 8.2. All models are capable of either vertical or horizontal airflow.Description. 48FCFM24A3A5-6F0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Models. 24 = 20 Tons. A = No Smoke Detector or CO 2 Sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu.Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB. View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,...InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES.Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas HeatFig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat38AU Gemini™ Commercial Split-System Air-Cooled Condensing Units & 40RU Air Handling Units. 38AUD 10-12 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 15 Ton Packaged Air Cooled Condenser Units, Dual Circuit, Family REVIT Files. 38AUD 20 Ton Packaged Air Cooled Condenser Units, Dual … Carrier Enterprise Mid-Atlantic Technical Support Site 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-1 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A3-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; BTU Input 90000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial;Lighter units make easy replacement. Most of Carrier’s 3--12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. Easy to maintain: Easy access handles by Carrier provide quick and easy access to all normally serviced components.

Carrier contractors are ready to help you create your ideal home environment. Find an Expertkeyboard_arrow_right. Explore HVAC Systems & Products. Learn about our innovative products and how they can help improve your comfort. Browse Productskeyboard_arrow_right. Learn Heating & Cooling Basics.. La vie nails clayton

carrier 48fc 15 ton

Permanently lubricated evaporator-fan motor. Totally enclosed condenser motors with permanently lubricated bearings. Low pressure and high-pressure switch protection. …SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005). 14 = 12.5 Ton C = Temp Standard Leak Econo w/PE(cent) ---17 = 15 Ton Vertical Only 20 = 17.5 Ton E = Enthalpy Standard Leak Econo w/Baro relief 24 = 20 Ton F = Enthalpy Standard Leak Econo w/PE(cent) 26 = 23 Ton --- Vertical Only N = Temp Ultra Low Leak Econo w/ baro relief Sensor Options P = Temp Ultra Low Leak Econo w/PE vert only Carrier Ton A/C-Only Rooftop Unit w/Economizer 50GCN06A1D5A0A0A0 208/230 -1. ... WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. ... Carrier® WeatherMaker® Rooftop Gas Heat Electric Cool Unit, 15 Ton, PH.InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N...American Airlines is ending the AirPass program, which offered fixed rates for travel and a ton of lucrative perks. While most travelers purchase airline tickets directly from the ...50FCQ 04 -28, 50GCQ 04-06 Single Package Rooftop Heat Pump Units with SystemVuTM Controls Version 3.X and Puron R-410A Refrigerant Controls, Start-Up, Operation and Troubleshooting Instructions IMPORTANT: This literature covers 50FCQ 04 -28 and 50GCQ 04-06 models with SystemVu controls version 3.X...S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andAir Conditioner Carrier 48FC Installation Instructions Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) Air Conditioner Carrier 48LJ Installation, Start-Up And Service Instructions ManualView and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ... View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,... 6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.Carrier 48TCED Manuals | ManualsLib. Check Details. Carrier 58UHV Product data | Manualzz. Check Details. carrier chiller data. Check Details. WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology. Check Details. Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check …American Airlines is ending the AirPass program, which offered fixed rates for travel and a ton of lucrative perks. While most travelers purchase airline tickets directly from the ...48TC*D/E units for installation in the United States contain use of Carrier's Staged Air Volume (SAV™) 2-speed indoor fan control system. This complies with the U.S. Department of Energy (DOE) efficiency standard of 2018. ... Fig.15 (size 08-16) for base rail details. See Fig. 6 (size 07) for thru-the-base charts.Carrier 48FC Installation Instructions (2 pages) Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory Manual is suitable for 4 more products: 48 GC 48 HC 48 LC 48 TCaccess it. Carrier r ooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: † Single cooling stage models are ….

Popular Topics